F226:Description:說(shuō)明:

The level of the DC bus voltage will be monitored by the drive controller. If

the DC bus voltage falls below a minimal threshold, the drive

independently shuts down according to the set error reaction.

直流母線(xiàn)電壓的水平將由驅動(dòng)控制器監控。如果直流母線(xiàn)電壓低于最小閾值根據設定的錯誤反應獨立關(guān)閉。


6.15力士樂(lè )伺服驅動(dòng)器1.jpg


Cause:原因:

1. The power source has been interrupted without first switching off

the drive enable (RF).

電源在未首先關(guān)閉的情況下中斷驅動(dòng)使能(RF)。

2. Disturbance in the power supply

電源干擾。


7.24力士樂(lè )驅動(dòng)器2.jpg


Remedy:排查思路:

For 1 Check the logic regarding the activation of the drive within

the connected control.

檢查內部驅動(dòng)器激活的邏輯連接的控件。


7.19力士樂(lè )驅動(dòng)器2_副本.jpg

For 2 Check the power supply.

檢查電源。

The error can be cleared by removing the control enable signal.

可以通過(guò)移除控制啟用信號來(lái)清除錯誤。

 